The ACR SMARTBUTTON comes with a one-year warranty, has a 10-year battery life,
has the ability to record over 2000 data points, and operates in a temperature
range of -10 deg. C to 85 deg. C (+14 deg. F to 185 deg. F).
The FREE ACR SMARTBUTTON READER
software is packed full of features including user selectable sampling rates,
programmable alarm thresholds, graph zooming and start delay.
Type: | Temperature |
Size: | 17 mm diameter x 6 mm height |
Weight: | 4g |
Battery: | 3.0 volt Lithium (typical life - 10 years) |
Resolution: | 8 bits - 0.5 deg. C (0.9 deg. F) |
Mounting: | User selectable |
Clock Accuracy: | ±2 seconds per month |
Sampling Methods: | Continuous (First-in, First-out), Stop when full |
PC Requirements: | IBM PC or 100% compatible Pentium 75 (minimum) with at least one free serial port, 16 MB of RAM memory, colour monitor & pointing device |
Software Requirements: | ACR SmartButton Reader™ for Windows - versions 95, 98, NT and 2000 |
Communication: | RS232 Serial/ACR SmartButton interface |