SHP-1

Back to Enerstat Residential Programmable Thermostats

SINGLE COMPRESSOR AUTO CHANGEOVER HEAT PUMP CONTROLLER
- 2 HEAT/ 1 COOL

GENERAL DESCRIPTION

The SHP-1 programmable controller is designed for new or replacement residential heat pump applications. The SHP-1 represents the latest in solid-state surface mount electronics and manufacturing techniques incorporated into an extremely low profile, ultra-slim white ABS plastic case. The SHP-1 contains a "user friendly" program along with an easy-to-read vertical LCD that displays current information and operation modes. A direct wire, easy-to-install subbase mounts on a standard vertical outlet box or any dry wall surface using anchors and hardware provided.

STANDARD FEATURES
  • Selectable Celsius or Fahrenheit temperature display.
  • Fan selector for continuous fan operation.
  • Built-in short cycle protection.
  • Electronic circuitry replaces conventional mechanical anticipator.
  • Internal switch to lock-out the keypad to prevent unauthorised tampering.
  • 45 second fan purge after heating and cooling call.
  • 12 hour or 24 hour clock.
  • Daylight Savings Time button to adjust the clock ±1 hour.
  • Does not require a battery (always maintains the last setpoint and mode of operation following power outages of any duration.)
  • Selectable 0 or B reversing valve outputs.
  • Dry contact relay outputs.
  • Built-in auxiliary heat light indicator
  • Two free lights.
  • 5-2 day programming with 4 events per day.
  • Lockable access cover.
  • Adjustable balance point (ODT option).
  • Temperature override (3 hours).
  • Continuous override (Hold).
  • Selectable LCD service symbols (selectable)
  • Outdoor temperature Sensor (optional).
  • Indoor Remote Temperature Sensor (optional).
  • Independent circuit switching (allows 24 Volt AC or DC power).
  • 1 C Heat/Cool separation.
  • Built-in anticipation & droop.
  • Minimum on/off times (2 or 4 minute selectable).

  • SPECIFICATIONS
    Rated Voltage 20-30 Vac, DC 24 Nominal
    Rated A.C Current: 0.050 Amps to 0.5 Amps continuous per output with surges to 1 Amp Max.
    Rated D.C. Current: 0.0 Amps to 0.5 Amps continuous per output with surges to 1 Amp Max.
    Control Range Cooling: 16 to 40 C in 1 C Steps
    Heating: 5 to 30 C in 1 C Steps
    Controller measurement range 0 to 48 C
    O.D.T. Measurement Range - 48 C to 48 C
    Control Accuracy ± 0.5 C At 20 C
    Minimum Deadband: (between heating and cooling) 1 °C
    Dimensions: 114mm x 102mm x 22mm
    Terminations: 24 Vac, 24 vac (C ), Y1, Y2, 0/B, W1, G
    Minimum wires required 7

    OUTPUT TERMINAL FUNCTIONS

    W1 Auxiliary Heat is energised as second stage heating or Emergency Heat
    Y1 Compressor is energised with a call for Heating or Cooling
    G Fan is energised with a call for Heating or Cooling or selected by pressing the Fan button
    R Independent Switching Voltage
    24 Vac 24 Vac Hot from the equipment transformer
    24 Vac (C) 24 Vac (Common) from the equipment transformer
    LED1 & LED2 Free lights for status or function indication
    RS2 & RS1 & RS+V Use to connect Outdoor Temperature Sensor option and/or Indoor Remote Sensor Option. Refer to the instructions included with the sensors.
    O Energises the reversing valve in cooling mode
    B Energises the reversing valve in heating mode

    Back to Enerstat Residential Programmable Thermostats